{"id":1710,"date":"2022-08-04T22:35:32","date_gmt":"2022-08-05T03:35:32","guid":{"rendered":"https:\/\/maximus.energy\/?p=1710"},"modified":"2022-10-20T10:39:51","modified_gmt":"2022-10-20T15:39:51","slug":"scintacor-neutron-detector","status":"publish","type":"post","link":"https:\/\/maximus.energy\/index.php\/2022\/08\/04\/scintacor-neutron-detector\/","title":{"rendered":"Scintacor Neutron Detector"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/maximus.energy\/index.php\/product\/scintacor-neutron-detection-screen\/\" data-type=\"URL\" data-id=\"https:\/\/maximus.energy\/index.php\/product\/scintacor-neutron-detection-screen\/\">Scintacor neutron detection sheet<\/a> is a giant <sup>6<\/sup>Li-scintillator based neutron detector suitable for registering thermal neutrons &#8211; Fig. 1. Thanks to <sup>6<\/sup>Li, the detector sensitivity per unit area is is very similar to the the sensitivity of a <sup>3<\/sup>He detector.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"870\" height=\"274\" data-attachment-id=\"1709\" data-permalink=\"https:\/\/maximus.energy\/scintacor\/\" data-orig-file=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?fit=1225%2C386&amp;ssl=1\" data-orig-size=\"1225,386\" data-comments-opened=\"1\" data-image-title=\"Scintacor\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?fit=870%2C274&amp;ssl=1\" src=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?resize=870%2C274&#038;ssl=1\" alt=\"\" class=\"wp-image-1709\" srcset=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?resize=1024%2C323&amp;ssl=1 1024w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?resize=300%2C95&amp;ssl=1 300w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?resize=768%2C242&amp;ssl=1 768w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?resize=600%2C189&amp;ssl=1 600w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?w=1225&amp;ssl=1 1225w\" sizes=\"auto, (max-width: 870px) 100vw, 870px\" \/><figcaption>Fig. 1. Scintacor neutron detector.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">This detector requires +12V power (60 mA) and produces short (10 us) positive polarity pulses with amplitude on the order of 1-2 volts. Just like any other thermal neutron detector, the Scintacor neutron detection sheets requires moderator to slow down fast neutrons.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal neutron spectrum of the Scintacor detector is shown on FIg. 2.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"870\" height=\"550\" data-attachment-id=\"1712\" data-permalink=\"https:\/\/maximus.energy\/index.php\/2022\/08\/04\/scintacor-neutron-detector\/scintacor-spectrum\/\" data-orig-file=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?fit=1129%2C713&amp;ssl=1\" data-orig-size=\"1129,713\" data-comments-opened=\"1\" data-image-title=\"Scintacor-Spectrum\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?fit=870%2C550&amp;ssl=1\" src=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?resize=870%2C550&#038;ssl=1\" alt=\"\" class=\"wp-image-1712\" srcset=\"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?resize=1024%2C647&amp;ssl=1 1024w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?resize=300%2C189&amp;ssl=1 300w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?resize=768%2C485&amp;ssl=1 768w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?resize=600%2C379&amp;ssl=1 600w, https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor-Spectrum.png?w=1129&amp;ssl=1 1129w\" sizes=\"auto, (max-width: 870px) 100vw, 870px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Note that the spectrum is the same as for a typical ZnS scintillator with no features corresponding to neutron energy. Therefore, this detector is suitable for thermal neutron counting only.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks to its huge size  (24&#8243; long by 6&#8243; wide in this example), <a href=\"https:\/\/maximus.energy\/index.php\/product\/scintacor-neutron-detection-screen\/\" data-type=\"URL\" data-id=\"https:\/\/maximus.energy\/index.php\/product\/scintacor-neutron-detection-screen\/\">Scintacor detector<\/a> is perfect for detecting thermal neutrons from weak spatially extended sources.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Scintacor neutron detection sheet is a giant 6Li-scintillator based neutron detector suitable for registering thermal neutrons &#8211; Fig. 1. Thanks to 6Li, the detector sensitivity per unit area is is very similar to the the sensitivity of a 3He detector. This detector requires +12V power (60 mA) and produces short (10 us) positive polarity pulses [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1709,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[20],"tags":[],"class_list":["post-1710","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-neutron-detection"],"jetpack_publicize_connections":[],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p9osz2-rA","jetpack_likes_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/maximus.energy\/wp-content\/uploads\/2022\/08\/Scintacor.png?fit=1225%2C386&ssl=1","_links":{"self":[{"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/posts\/1710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/comments?post=1710"}],"version-history":[{"count":3,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/posts\/1710\/revisions"}],"predecessor-version":[{"id":1714,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/posts\/1710\/revisions\/1714"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/media\/1709"}],"wp:attachment":[{"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/media?parent=1710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/categories?post=1710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/maximus.energy\/index.php\/wp-json\/wp\/v2\/tags?post=1710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}